Fire-stop penetration seals in Ochtrup

Wall and ceiling penetrations in Ochtrup sealed audit-ready, installed to approval, tracked in penetration plans for the consultant's sign-off.

Walkthrough in OchtrupDefect list includedFixed offer
Ochtrup

What a penetration seal achieves.

Every wall penetration in Ochtrup that crosses a fire-compartment boundary needs documentation: installer. Consultants check this every year. Insurers reference it at renewal. A missing seal is the kind of finding that raises premiums.

Penetration systems for Ochtrup.

The system depends on opening size, occupancy density and wall type.

  1. 01

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan. Audit-ready in Ochtrup.

  2. 02

    Stock documentation

    Take over multi-brand stock in Ochtrup, consolidate in the penetration plan, prepare for consultant sign-off. Audit-ready in Ochtrup.

  3. 03

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line.

  4. 04

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution. Specified per approval in Ochtrup.

  5. 05

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables.

  6. 06

    Cable seal in wall

    Classic in Ochtrup stock: cables through F30/F90 wall, mineral wool with coating or board with collars. Audit-ready in Ochtrup.

Where we install seals in Ochtrup.

Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Ochtrup. Standard scope in Ochtrup.
Cable trays
Tray penetrations with box seals or aggregate seals.
Stock survey
Take over multi-brand stock in Ochtrup, inspect, transfer into penetration plan, prepare for authorities. Standard scope in Ochtrup.
Duct lines
Fire dampers, duct seals — schools, care, offices in Ochtrup.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Ochtrup. Standard scope in Ochtrup.

Standards.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Ochtrup buildings.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Ochtrup.

What penetration seals cost in Ochtrup.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Ochtrup

Fixed offer after walkthrough in Ochtrup.

Fire stops in Ochtrup — FAQ.

  • Yes — as long as each position has an approval and the documentation is consistent. We take over stock brand-neutrally.

Have your seals checked for Ochtrup.

Call us — we take over the seal stock in Ochtrup and continue it.

Call+49 2861 8114387