24h fire-protection emergency

Fire door jammed, gate won't close, SHEV alarm from faulty smoke detector — we respond within 24 hours across NRW. With dedicated contact under service contract.

Call emergency
24h responseNRW-wideDedicated contact
24h fire-protection emergency

When fire protection fails, speed is safety.

Abels Brandschutz responds to failures on safety-critical fire-protection installations across all of North Rhine-Westphalia within 24 hours — weekdays and weekends. Typical calls: a fire door T30 or T90 jammed after a break-in attempt, a fire gate in a logistics warehouse no longer closing, a hold-open device per DIN 14677 released without cause, a faulty smoke switch on a smoke-and-heat-extraction system per DIN 18232-2. For operators these failures are more than a comfort issue: a fire door stuck open breaks the fire compartment, a blocked escape door violates German Workplace Regulation ASR A2.3, and a non-functioning hold-open is treated by insurers as 'not operational'. Service-contract customers receive priority, a dedicated contact and reduced call-out rates outside office hours.

Variants

Which variant fits depends on the installation context, the existing building and the fire-protection concept — we advise per project.

Standard configuration

Cost-efficient solution for the most common installation contexts — tested systems from established manufacturers.

from €180

Bespoke configuration

For non-standard sizes, installation contexts or higher requirements driven by the fire-protection concept or expert reports.

from €280

Existing buildings & retrofit

Recertification of existing components or phased replacement — coordinated around live operations.

from €380

Service-contract customers with annual service plan pay reduced rates and have guaranteed response under 24h.

Emergency callers across NRW.

We cover every typical building type — from residential to industrial complexes with hundreds of components per site.

01

Logistics & industry

Fire gates in high-bay warehouses, workshop doors, fire sliding gates in production lines — downtime blocks expensive logistics. We prioritise industrial customers running 24h shifts.

02

Hospitals & care facilities

Safety-critical around the clock — an open fire door in an operating area or ward must be fixed within hours. We come at night.

03

Schools & public authorities

Escape doors with panic lock DIN EN 1125 must not jam. Where school operations are blocked by a defective fire installation, we step in the same day.

04

Property managers

Fire doors in residential stairwells, basement closures, lift-shaft doors. Framework agreements with property managers allow direct dispatch without owner approval.

05

Architects & general contractors

Acceptance test imminent and the fire door is not approval-ready — we attend before the appointment and restore function.

  • MBO § 14

    Building Code NRW — fire protection

    Fire compartments must be operational at all times. A non-closing fire door violates the Building Code — the operator is liable.

  • ArbStättV / ASR A2.3

    Escape routes always usable

    Escape doors with panic lock DIN EN 1125 must be openable at any time. A jammed escape door is treated as immediate endangerment of employees.

  • DIN 14677

    Maintenance of hold-open systems

    Hold-open devices must be function-checked monthly. After a non-fire trigger the cause must be documented and rectified.

  • DIN 18232-2

    SHEV — smoke and heat extraction

    SHEV installations must be serviced annually, manual trip points checked half-yearly. Emergency batteries replaced every 4 years.

  • VdS 2095

    Insurance requirement

    Property insurers require functional fire-protection installations. A known defect not remedied within a 'reasonable time' may trigger reduced settlement.

We help with these failures.

NRW-wide, exclusively with our own installers — no subcontractors.

24h response — actual

We promise 24h response and meet it. Contract customers receive their call-out under 6 hours on average, measured over 12 months.

Brand-agnostic service

We repair doors and gates from all common manufacturers — Hörmann, Novoferm, Teckentrup, Schörghuber, Kone, GEZE, Dorma. You don't need to call the original maker.

Remote diagnosis before dispatch

Describe the fault on the phone — in 40% of cases we resolve it without a call-out. You save the call-out fee and we save the trip.

On-site temporary fix guaranteed

If the spare part is not immediately available, we secure the fire compartment with an emergency closure or approved temporary measure — you remain operationally insured.

Full documentation for insurance

Every call-out ends with a photo log, defect list and recommendation — directly usable for insurers and surveyors.

  1. 01

    Fire door jams or fails to self-close

    Door closer broken or misadjusted, leaf warped after burglary attempt, frame anchor loose, fire seal torn out, anchor screw broken. We repair or replace the closer (DIN EN 1154), adjust the closing sequence on double-leaf doors, fit new fire seals and restore self-closing function.

  2. 02

    Fire gate won't close

    Hold-open magnet failed, release logic disturbed by power loss, light barrier defective, mechanical obstruction in the rail, broken spring on a sectional gate. We trip the gate manually, secure the fire compartment with an emergency closure or temporary barrier, and plan material delivery for the final repair.

  3. 03

    Hold-open released without fire

    Smoke switch falsely triggered by dust or steam, power loss, control unit faulty, time-lock error. We reset the system, locate the cause, clean or replace the smoke switch and inspect the full installation per DIN 14677.

  4. 04

    Panic lock or escape-door fitting defective

    Push bar per DIN EN 1125 jams, bolt won't retract, anti-panic lock blocked. Safety-critical — a non-openable escape door violates the Workplace Ordinance. Immediate measure plus replacement within 24h.

  5. 05

    SHEV system fails to release or constant false alarm

    Ventilation flaps don't open, manual trip point dead, emergency battery discharged, control unit faulty. We inspect the trip chain, power supply and mechanical drives per DIN 18232-2.

  6. 06

    Fire damper in HVAC blocked

    Fusible link not reset, damper stuck mid-position, K90/EI 90 S function not assured. Temporary safeguarding of the fire compartment and replacement per DIN EN 15650.

Emergency details.

Call now — we respond.

Describe the failure on the phone. We give a remote diagnosis and plan the call-out.