Steel
Standard for T90 — robust, available in all sizes, best availability and the lowest price.
90 minutes of fire resistance for maximum security. T90 doors are required in fire walls, high-rise stairwells, industrial buildings, server rooms and special-construction buildings. Classified EI₂90 to EN 13501-2 — three times the protection of T30.

A T90 fire door withstands fire and heat in the standard fire test for at least 90 minutes. Classified T90 to DIN 4102-5 or EI₂90 to EN 13501-2. T90 is significantly more demanding than T30: higher requirements for the leaf, frame, wall type and joint. T90 doors are usually combined with smoke control ("-RS") and frequently with hold-open systems — they remain open in daily use and only close automatically in a fire. The fire protection concept of the building and the industrial-construction directive or the relevant special-construction code govern.
T90 is technically demanding. We recommend the variant suited to wall, fire load and appearance.
Standard for T90 — robust, available in all sizes, best availability and the lowest price.
For premium interior areas, foyers and representative fire-wall transitions — slim profiles, high-end appearance.
PROMAGLAS or Contraflam — possible but significantly more expensive than solid or T30 glass.
Standard for openings up to about 1,250 mm wide.
For wide industrial openings and transport routes — with mandatory closing-sequence control.
Open in daily use, closing automatically in a fire via fire alarm or smoke detector.
T90 demands experience. We bring statics, frame and wall combination into an approved combination — and document every step.
Review of statics, wall type and frame choice — based on your drawings and on site.
Hörmann, Novoferm, Teckentrup, Schüco — with approval and test certificate.
Trained fitters with current manufacturer records — a precondition for valid approval.
Declaration of conformity, approval label, installation record — audit-proof for authorities and insurers.
Annual inspection per DIN 14677 with logbook and defect record.
Separate building sections and are mandated by BauO NRW § 28 — standard requirement T90.
Above a defined building height (high-rise directive / HHR NRW) — T90-RS doors with self-closing.
Per the industrial-construction directive — separation of fire compartments, storage of hazardous substances.
Asset protection for IT infrastructure — often combined with access control and climate sealing.
Hospitals, assembly venues, hotels — where the special-construction code requires it.
Storage, workshops, transformer stations — wherever the fire-load comparison demands T90.
T90 doors are 2–4× more expensive than comparable T30 specifications. Main reasons: heavier leaf, more stable frame, stricter joint, often non-standard sizes.
Prices are indicative including VAT. A binding quote follows an on-site survey and substrate check.
Pillar page covering all classes and configurations.
Standard for corridors, stairwells, apartment entrances.
Replacement in the existing stock, often after a defects list.
Complementary for steel beams and fire-compartment elements.
Inspection and maintenance per DIN 14677.
Which class is legally required when.
Are you planning a fire wall or a high-risk area? We come on site, check wall and statics and deliver a binding quote.