T90 Fire Doors

90 minutes of fire resistance for maximum security. T90 doors are required in fire walls, high-rise stairwells, industrial buildings, server rooms and special-construction buildings. Classified EI₂90 to the applicable proofs of usability — three times the protection of T30.

Request a quote
90 min fire resistanceFire wall · industry · server roomSteel · special aluminium
T90 Fire Doors

Triple protection — for fire walls and high-risk areas.

A T90 fire door withstands fire and heat in the standard fire test for at least 90 minutes. Classified T90 to the applicable proofs of usability or EI₂90 to the applicable proofs of usability. T90 is significantly more demanding than T30: higher requirements for the leaf, frame, wall type and joint. T90 doors are usually combined with smoke control ("-RS") and frequently with hold-open systems — they remain open in daily use and only close automatically in a fire. The fire protection concept of the building and the industrial-construction directive or the relevant special-construction code govern.

Predominantly steel — aluminium and glass as special cases.

T90 is technically demanding. We recommend the variant suited to wall, fire load and appearance.

Steel

Standard for T90 — robust, available in all sizes, best availability and the lowest price.

from €1,800

Special aluminium

For premium interior areas, foyers and representative fire-wall transitions — slim profiles, high-end appearance.

from €2,800

With T90 glazing

Fire-rated glazing — possible but significantly more expensive than solid or T30 glass.

from €4,500

Single-leaf

Standard for openings up to about 1,250 mm wide.

from €6,000

Double-leaf

For wide industrial openings and transport routes — with mandatory closing-sequence control.

With hold-open system

Open in daily use, closing automatically in a fire via fire alarm or smoke detector.

Prices are indicative including VAT. A binding quote follows an on-site survey and substrate check.

Where T90 doors are mandatory.

We cover every typical building type — from residential to industrial complexes with hundreds of components per site.

01

Fire walls

Separate building sections and are mandated by BauO NRW § 28 — standard requirement T90.

02

High-rise stairwells

Above a defined building height (high-rise directive / HHR NRW) — T90-RS doors with self-closing.

03

Industrial buildings

Per the industrial-construction directive — separation of fire compartments, storage of hazardous substances.

04

Server rooms & data centres

Asset protection for IT infrastructure — often combined with access control and climate sealing.

05

Plant rooms in special buildings

Hospitals, assembly venues, hotels — where the special-construction code requires it.

06

Separation of high fire loads

Storage, workshops, transformer stations — wherever the fire-load comparison demands T90.

  • Wall

    Minimum wall thickness & load capacity

    Higher requirements for concrete, masonry or specific drywall constructions — substrate check before installation is mandatory.

  • Frame

    Heavier, more stable frame

    T90 doors weigh significantly more than T30 — the frame must be correspondingly load-bearing and approved in the tested wall combination.

  • Joint

    Fire-protective mortar mandatory

    Stricter testing of the joint — only fire-protective mortar per the approval, no construction foam.

  • Glazing

    T90 glass — possible but expensive

    Fire-rated glazing EI₂90 is possible, significantly more expensive than T30 glass.

  • Closing sequence

    Mandatory for double-leaf

    Double-leaf T90 doors require closing-sequence control to ensure correct closing order.

  • Documentation

    Declaration of conformity & inspection duty

    Every T90 installation is documented with declaration of conformity, approval label and installation record; annual inspection is required afterwards.

T90 — from planning to maintenance.

T90 demands experience. We bring statics, frame and wall combination into an approved combination — and document every step.

NRW-wide

Aachen to Bielefeld, Lower Rhine to Sauerland — survey usually within five working days.

Our own installers

No subcontractors. Warranty work and maintenance always trace back to the same people.

Maintenance contracts

We schedule appointments proactively. Inspection record for the fire authority comes with every visit.

  1. 01

    Planning support

    Review of statics, wall type and frame choice — based on your drawings and on site.

  2. 02

    Supply of certified systems

    Brand-agnostic — all common systems with approval and test certificate.

  3. 03

    Installation by certified team

    Trained fitters with current manufacturer records — a precondition for valid approval.

  4. 04

    Documentation

    Declaration of conformity, approval label, installation record — audit-proof for authorities and insurers.

  5. 05

    Maintenance & inspection

    Annual inspection in accordance with the applicable proofs of usability with logbook and defect record.