Fire-stop penetration seals in Schöppingen

Wall and ceiling penetrations in Schöppingen sealed audit-ready, installed to approval, tracked in penetration plans for the consultant's sign-off.

Request walkthrough+49 2861 8114387
Wall · ceilingS30 · S60 · S90With penetration plan
Schöppingen

What a penetration seal achieves.

Penetration seals are approved closures of wall and ceiling openings. They hold the rated wall's integrity for the same duration the wall itself is rated for — 30, 60 or 90 minutes. Without a seal, every cable, pipe or duct that crosses the wall becomes a direct path for flames and smoke.

Penetration systems for Schöppingen.

The system depends on opening size, occupancy density and wall type.

  1. 01

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan. Specified per approval in Schöppingen.

  2. 02

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line. Audit-ready in Schöppingen.

  3. 03

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables. Audit-ready in Schöppingen.

  4. 04

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution.

  5. 05

    Cable seal in wall

    Classic in Schöppingen stock: cables through F30/F90 wall, mineral wool with coating or board with collars. Documented in the property log in Schöppingen.

  6. 06

    Stock documentation

    Take over multi-brand stock in Schöppingen, consolidate in the penetration plan, prepare for consultant sign-off. Audit-ready in Schöppingen.

Where we install seals in Schöppingen.

Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Schöppingen.
Duct lines
Fire dampers, duct seals — schools, care, offices in Schöppingen.
Stock survey
Take over multi-brand stock in Schöppingen, inspect, transfer into penetration plan, prepare for authorities.
Cable trays
Tray penetrations with box seals or aggregate seals.
Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Schöppingen.

Standards.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Schöppingen.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Schöppingen buildings.

What penetration seals cost in Schöppingen.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Schöppingen

Fixed offer after walkthrough in Schöppingen.

Fire stops in Schöppingen — FAQ.

  • Yes — as long as each position has an approval and the documentation is consistent. We take over stock brand-neutrally.

Have your seals checked for Schöppingen.

Call us — we take over the seal stock in Schöppingen and continue it.

Call+49 2861 8114387