Smoke-tight assemblies

Smoke-tight doors in accordance with the applicable proofs of usability prevent smoke spread in escape and rescue routes. Marked "-RS". Usually combined with T30 or T90 fire resistance. We advise, supply and install across NRW.

Request a quote
applicable proof of usabilityRS / SAaT30-RS · T90-RS
Smoke-tight assemblies

Smoke-tight — not necessarily fire-resistant.

A smoke-tight assembly in accordance with the applicable proofs of usability holds back smoke for over 30 minutes at a 200 °C temperature test. Classification "SAa" or combined as "T30-RS" / "T90-RS". Smoke seals are mandatory in necessary corridors, stairwells and escape routes per state building code — wherever smoke would make an escape route impassable. Typical: circumferential seals, threshold seal, tested closing system.

Which execution fits.

Which variant fits depends on the installation context, the existing building and the fire-protection concept — we advise per project.

RS door (smoke only)

No fire resistance — smoke-tight only. Rare, mostly basements or low fire load.

On request

T30-RS

Most common combination. 30-min resistance + smoke-tight. Standard in flats, offices, hotels.

T90-RS

For high-rises and firewalls with smoke-seal requirement.

RS frame only

Frame replacement in existing buildings — when the leaf remains.

All prices excl. VAT. Maintenance contracts are quoted on a per-unit basis.

Where we work

We cover every typical building type — from residential to industrial complexes with hundreds of components per site.

01

Residential

Apartment buildings, stairwells, transitions to boiler rooms and underground garages — usually with smoke-protection properties.

02

Industry & logistics

Separation of production, storage and administration plus protection of mechanically loaded plant.

03

Public buildings

Schools, hospitals and administrative buildings under NRW special-buildings regulations — often combined with hold-open systems.

  • applicable proof of usability/-2

    Smoke-tight assemblies

    Requirements and test methods for smoke-tight doors.

  • applicable proof of usability

    Smoke leakage test

    European test standard — complements applicable proof of usability.

  • applicable proof of usability

    Classification Sm / Sa

    Sm (room-temperature) and Sa (warm-smoke at 200 °C).

  • BauO NRW

    Building code

    Smoke-seal obligation in necessary corridors, stairwells, escape routes.

Planning, install, retrofit, service.

NRW-wide, exclusively with our own installers — no subcontractors.

NRW-wide

Aachen to Bielefeld, Lower Rhine to Sauerland — survey usually within five working days.

Our own installers

No subcontractors. Warranty work and maintenance always trace back to the same people.

Maintenance contracts

We schedule appointments proactively. Inspection record for the fire authority comes with every visit.

  1. 01

    Building-code review

    What does the fire-concept require? T30-RS or T90-RS? Escape-route relevance?

  2. 02

    Install with leak test

    Installation per manufacturer certificate incl. threshold seal, functional check, smoke-cartridge leak test.

  3. 03

    Retrofit existing leaf

    RS retrofit of an existing T30 via seals and new frame — often a cost-effective solution.

  4. 04

    Annual service

    Check closers, seals, self-closing — with protocol.

Smoke-tight details.

Request an RS door.

We clarify building-code requirements, assess retrofit options and deliver installation-ready with leak protocol.