Apartment buildings, stairwells, transitions to boiler rooms and underground garages — usually with smoke-protection properties.
Fixed suppression systems protect assets that humans cannot — server rooms, archives, warehouses, tank sites. We plan, service and test sprinkler, gas and foam systems in accordance with the applicable proofs of usability.

Fire-suppression systems are fixed installations that automatically extinguish fires without human intervention. Sprinklers (water) protect production and storage, gas (CO₂, Inergen, Novec) protects IT and archives, foam protects tanks and hangars. Planning, install and service follow VdS guidelines (CEA 4001 for sprinkler, VdS 2093 for gas) and applicable proof of usability. Annual service by the installer or a VdS-approved service firm is mandatory for insurance cover.
Which variant fits depends on the installation context, the existing building and the fire-protection concept — we advise per project.
Pipework permanently filled with water. Standard for production, storage, offices — economical, low-maintenance. Not for frost-exposed areas.
Pipework under compressed air, water only after release. For warehouses below 4 °C.
For electrical plants, transformers, cable basements — displaces oxygen, residue-free. Personal hazard to consider.
People-safe gases for server and archive rooms. No water damage, residue-free.
For tank sites, oil/fuel storage, hangars. Suffocates burning liquids with foam blanket.
All prices excl. VAT. Maintenance contracts are quoted on a per-unit basis.
We cover every typical building type — from residential to industrial complexes with hundreds of components per site.
Apartment buildings, stairwells, transitions to boiler rooms and underground garages — usually with smoke-protection properties.
Separation of production, storage and administration plus protection of mechanically loaded plant.
Schools, hospitals and administrative buildings under NRW special-buildings regulations — often combined with hold-open systems.
German VdS guideline — planning, install, service of sprinklers.
European standard — matches CEA 4001 in most aspects.
Guideline for planning, install, service of CO₂ systems.
Guideline for inert-gas and HFC systems.
Guideline for heavy-, medium-, light-expansion foam.
NRW-wide, exclusively with our own installers — no subcontractors.
Aachen to Bielefeld, Lower Rhine to Sauerland — survey usually within five working days.
No subcontractors. Warranty work and maintenance always trace back to the same people.
We schedule appointments proactively. Inspection record for the fire authority comes with every visit.
Site survey, hazard class, pipe-network sizing, VdS-compliant planning.
Pipework, sprinkler heads, alarm valve station, pump set. Handover by VdS inspector.
Valve tests, pump run, alarm release, spray-pattern check, logbook.
Pipework replacement, re-zoning, extension for new build, VdS re-approval.
We assess the hazard class, size the right system and deliver planning, install and service from one hand.