Fire-stop penetration seals in Heek

Wall and ceiling penetrations in Heek sealed audit-ready, installed to approval, tracked in penetration plans for the consultant's sign-off.

Walkthrough in HeekDefect list includedFixed offer
Heek

What a penetration seal achieves.

Every wall penetration in Heek that crosses a fire-compartment boundary needs documentation: date. Consultants check this every year. Insurers reference it after a loss. A missing seal is the kind of finding that gets cited in damage reports.

Penetration systems for Heek.

The system depends on opening size, occupancy density and wall type.

  1. 01

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan.

  2. 02

    Cable seal in wall

    Classic in Heek stock: cables through F30/F90 wall, mineral wool with coating or board with collars. Specified per approval in Heek.

  3. 03

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables.

  4. 04

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution.

  5. 05

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line. Documented in the property log in Heek.

  6. 06

    Stock documentation

    Take over multi-brand stock in Heek, consolidate in the penetration plan, prepare for consultant sign-off.

Where we install seals in Heek.

Cable trays
Tray penetrations with box seals or aggregate seals.
Duct lines
Fire dampers, duct seals — schools, care, offices in Heek. Standard scope in Heek.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Heek. Standard scope in Heek.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Heek.
Stock survey
Take over multi-brand stock in Heek, inspect, transfer into penetration plan, prepare for authorities. Standard scope in Heek.
Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus.

Standards.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Heek buildings.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Heek.

What penetration seals cost in Heek.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Heek

Fixed offer after walkthrough in Heek.

Fire stops in Heek — FAQ.

  • At least annually as part of maintenance — and after every cable/pipe change. Maintenance log mandatory in Heek.

Have your seals checked for Heek.

Call us — we take over the seal stock in Heek and continue it.

Call+49 2861 8114387