Steel
Standard, robust, economical. First choice for residential, commercial, plant rooms and underground car parks.
30 minutes of fire resistance, installed to standard. T30 is the most common fire-door class: corridors, stairwells, apartment entrances, plant rooms. Classified EI₂30 to EN 13501-2 (national T30 to DIN 4102-5) — tested as a complete assembly of leaf, frame, hardware and seals.

A T30 fire door withstands fire and heat in the standard fire test for at least 30 minutes. The test covers integrity (E), insulation (I) and mechanical resistance per EN 1634-1. Classification is T30 to DIN 4102-5 or EI₂30 to EN 13501-2 — both designations are recognised in Germany. A T30 door is self-closing and forms — together with frame, hardware and seals — a single approved assembly. With the suffix "-RS" it is additionally smoke-tight per DIN 18095 — required wherever escape routes must remain free of smoke.
The choice depends on appearance, fire load and installation context. We recommend based on your fire protection concept.
Standard, robust, economical. First choice for residential, commercial, plant rooms and underground car parks.
Premium appearance — for residential, office and representative areas. CPL or real-wood veneer.
Light, slim profiles, high-end appearance. For special applications and façade interfaces.
Fire-rated glazing EI₂30 — for more daylight in corridors and stairwells.
Standard for openings up to 1,250 mm wide. Quick availability, lowest cost.
For wide openings and transport routes — with closing-sequence control.
Consulting, supply, installation and maintenance — one contact, one responsibility.
Manufacturer, configuration, frame, hardware — based on your fire protection concept and the installation context.
Hörmann, Novoferm, Teckentrup, Schüco — with approval, test certificate and data plate.
With current manufacturer training records — a precondition for valid approval.
Replacement of uncertified doors — including in occupied buildings.
Regular inspection with logbook, defect record and scheduled follow-up.
Multi-occupancy residential, offices, commercial — separation of escape routes from adjoining uses.
Per BauO NRW depending on building class — usually as T30-RS in multi-storey residential blocks.
Boiler room, service entry room, lift shaft — separation from rooms with elevated fire load.
Between apartments, commercial units and common areas — defined in the fire protection concept and the state building code.
Transition from the stairwell to the basement — typically T30-RS.
Access from the underground car park to the stairwell — covered by the special-construction code (GarStVO).
A single-leaf T30 steel door in standard sizes starts at around €800. With frame, hardware, glazing and installation, €1,500 – €3,500 is realistic.
Prices are indicative including VAT. A binding quote follows an on-site survey or a drawings review.
Pillar page covering all classes, configurations and standards.
For fire walls and high-risk areas.
Replacement in the existing stock, often after a defects list.
Smoke-tightness without a fire-resistance rating.
Inspection and maintenance per DIN 14677.
When fire doors are legally mandated.
Need a T30 door? Send us measurements or drawings — we respond within one business day with a no-obligation quote.