Fire-stop penetration seals in Duisburg

Cable and pipe penetrations for walls and ceilings in Duisburg — approved, tested, documented. Promat, Hilti, Würth · S30 to S90 · existing stock, new build, retrofit.

Promat · Hilti · WürthExisting & newAudit-ready documentation
Duisburg

What a penetration seal achieves.

Every wall penetration in Duisburg that crosses a fire-compartment boundary needs documentation: photo of the closed seal. Consultants check this every year. Insurers reference it after a loss. A missing seal is the kind of finding that gets cited in damage reports.

Penetration systems for Duisburg.

The system depends on opening size, occupancy density and wall type.

  1. 01

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line. Specified per approval in Duisburg.

  2. 02

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution. Specified per approval in Duisburg.

  3. 03

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan.

  4. 04

    Stock documentation

    Take over multi-brand stock in Duisburg, consolidate in the penetration plan, prepare for consultant sign-off.

  5. 05

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables. Documented in the property log in Duisburg.

  6. 06

    Cable seal in wall

    Classic in Duisburg stock: cables through F30/F90 wall, mineral wool with coating or board with collars.

Where we install seals in Duisburg.

Stock survey
Take over multi-brand stock in Duisburg, inspect, transfer into penetration plan, prepare for authorities. Standard scope in Duisburg.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Duisburg.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Duisburg.
Duct lines
Fire dampers, duct seals — schools, care, offices in Duisburg. Standard scope in Duisburg.
Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus.
Cable trays
Tray penetrations with box seals or aggregate seals. Standard scope in Duisburg.

Standards.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Duisburg.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Duisburg buildings.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

What penetration seals cost in Duisburg.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Duisburg

Fixed offer after walkthrough in Duisburg.

Fire stops in Duisburg — FAQ.

  • A penetration plan documents every seal in the building — location, system, date, installer. Mandatory for public buildings, special-use, larger properties in Duisburg.

Have your seals checked for Duisburg.

Walkthrough in Duisburg → defect list → fixed offer.