Fire-stop penetration seals in Bottrop

Cable and pipe penetrations for walls and ceilings in Bottrop — approved, tested, documented. Promat, Hilti, Würth · S30 to S90 · existing stock, new build, retrofit.

Wall · ceilingS30 · S60 · S90With penetration plan
Bottrop

What a penetration seal achieves.

Every wall penetration in Bottrop that crosses a fire-compartment boundary needs documentation: photo of the closed seal. Consultants check this every year. Insurers reference it in the schedule. A missing seal is the kind of finding that raises premiums.

Penetration systems for Bottrop.

The system depends on opening size, occupancy density and wall type.

  1. 01

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan. Documented in the property log in Bottrop.

  2. 02

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line.

  3. 03

    Cable seal in wall

    Classic in Bottrop stock: cables through F30/F90 wall, mineral wool with coating or board with collars. Documented in the property log in Bottrop.

  4. 04

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables.

  5. 05

    Stock documentation

    Take over multi-brand stock in Bottrop, consolidate in the penetration plan, prepare for consultant sign-off. Documented in the property log in Bottrop.

  6. 06

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution. Specified per approval in Bottrop.

Where we install seals in Bottrop.

Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus. Standard scope in Bottrop.
Stock survey
Take over multi-brand stock in Bottrop, inspect, transfer into penetration plan, prepare for authorities. Standard scope in Bottrop.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Bottrop. Standard scope in Bottrop.
Duct lines
Fire dampers, duct seals — schools, care, offices in Bottrop.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Bottrop.
Cable trays
Tray penetrations with box seals or aggregate seals.

Standards.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Bottrop.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Bottrop buildings.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

What penetration seals cost in Bottrop.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Bottrop

Fixed offer after walkthrough in Bottrop.

Fire stops in Bottrop — FAQ.

  • Yes — as long as each position has an approval and the documentation is consistent. We take over stock brand-neutrally.

Have your seals checked for Bottrop.

Walkthrough in Bottrop → defect list → fixed offer.

Call+49 2861 8114387