Fire-rated gate maintenance

Fire-rated gates require maintenance — annually, by a specialist contractor, with complete documentation. Failing to maintain risks loss of insurance cover and personal liability. We deliver compliant maintenance for your gates — optionally on a framework contract with predictable costs.

Annual maintenance with log bookExpert inspection includedBrand-agnostic — all common systems
Fire-rated gate maintenance

Meet the obligation, avoid the liability.

Maintaining fire-rated gates is not optional. applicable proof of usability, the German Industrial Safety Ordinance (BetrSichV), ASR A1.7 and the manufacturer specifications oblige operators to perform regular maintenance — at least once a year, by a specialist contractor, with expert inspection in accordance with the applicable proofs of usability. Failure means loss of insurance cover, personal liability of management and possible regulatory shutdown. We deliver maintenance completely and verifiably — with maintenance record, defect list, photo documentation and entry in the inspection log book.

Variants

Which variant fits depends on the installation context, the existing building and the fire-protection concept — we advise per project.

Standard configuration

Cost-efficient solution for the most common installation contexts — tested systems from established manufacturers.

On request

Bespoke configuration

For non-standard sizes, installation contexts or higher requirements driven by the fire-protection concept or expert reports.

Existing buildings & retrofit

Recertification of existing components or phased replacement — coordinated around live operations.

All prices excl. VAT. Maintenance contracts are quoted on a per-unit basis.

Where we work

We cover every typical building type — from residential to industrial complexes with hundreds of components per site.

01

Residential

Apartment buildings, stairwells, transitions to boiler rooms and underground garages — usually with smoke-protection properties.

02

Industry & logistics

Separation of production, storage and administration plus protection of mechanically loaded plant.

03

Public buildings

Schools, hospitals and administrative buildings under NRW special-buildings regulations — often combined with hold-open systems.

  • applicable proof of usability

    Maintenance principles

    Defines maintenance, inspection, repair and improvement as elements of upkeep.

  • BetrSichV

    Industrial Safety Ordinance

    Obliges the employer to inspect work equipment regularly — including fire-rated gates.

  • ASR A1.7

    Technical rules for workplaces

    Governs doors and gates in workplaces — maintenance and operability are mandatory.

  • applicable proof of usability

    Expert inspection

    Describes professional inspection of safety-relevant components.

  • Manufacturer specs

    Maintaining approval

    The DIBt approval of each gate is valid only when maintained per manufacturer specifications.

What we check during maintenance.

Systematic, standards-compliant, documented — every point is recorded in the maintenance protocol.

Predictable costs

Fixed annual price, no surprises — ideal for budgeting and property management.

Automatic scheduling

We remind you and book appointments proactively — no missed deadlines.

Legal certainty

Complete proof for authorities, insurers and expert assessors.

Priority on repairs

Customers with maintenance contracts are prioritised when faults occur.

Discounts & emergency hotline

Discounted spare parts, optional 24-hour service for premium contracts.

Bundling possible

Doors, gates and hold-open systems on one contract — one appointment, one contact, one record.

  1. 01

    Closing behaviour

    Closing speed, complete closure, end position — checked and adjusted as needed.

  2. 02

    Seals

    Condition, tightness, wear — replaced if needed.

  3. 03

    Drive & motor

    Power, bearings, noise behaviour, lubrication.

  4. 04

    Controls

    Function, parameters, trigger logic, self-test.

  5. 05

    Safety devices

    Light barrier, contact strip, emergency stop, anti-crush.

  6. 06

    Limit switches

    Function and position, adjustment.

  7. 07

    Smoke detector & hold-open

    Function, sensitivity, trigger time.

  8. 08

    Mechanical components

    Guide, bearings, slats or panels — wear inspection.

  9. 09

    Locking & locks

    Function, security, adjustment if required.

  10. 10

    Signage & labelling

    Present, legible, standards-compliant.

Maintenance — explained.

Request a maintenance contract.

Send us number of gates, manufacturer (if known) and last service date — we respond within 24 hours with a quote.

Call+49 2861 8114387