Fire-stop penetration seals in Winterberg

Sealing what needs to be sealed in Winterberg and Kreis Hochsauerlandkreis. Cable seals, pipe stops, combined penetrations. Soft, hard or mortar seals.

Request walkthrough+49 2861 8114387
Promat · Hilti · WürthExisting & newAudit-ready documentation
Winterberg

What a penetration seal achieves.

Penetration seals are DIN-validated closures of wall and ceiling openings. They hold the rated wall's integrity for the same duration the wall itself is rated for — 30, 60 or 90 minutes. Without a seal, every cable, pipe or duct that crosses the wall becomes a breach for flames and smoke.

Penetration systems for Winterberg.

The system depends on opening size, occupancy density and wall type.

  1. 01

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line.

  2. 02

    Cable seal in wall

    Classic in Winterberg stock: cables through F30/F90 wall, mineral wool with coating or board with collars. Specified per approval in Winterberg.

  3. 03

    Stock documentation

    Take over multi-brand stock in Winterberg, consolidate in the penetration plan, prepare for consultant sign-off.

  4. 04

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution.

  5. 05

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan. Audit-ready in Winterberg.

  6. 06

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables. Documented in the property log in Winterberg.

Where we install seals in Winterberg.

Cable trays
Tray penetrations with box seals or aggregate seals.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Winterberg.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Winterberg. Standard scope in Winterberg.
Stock survey
Take over multi-brand stock in Winterberg, inspect, transfer into penetration plan, prepare for authorities. Standard scope in Winterberg.
Duct lines
Fire dampers, duct seals — schools, care, offices in Winterberg.
Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus.

Standards.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Winterberg.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Winterberg buildings.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

What penetration seals cost in Winterberg.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Winterberg

Fixed offer after walkthrough in Winterberg.

Fire stops in Winterberg — FAQ.

  • A penetration plan documents every seal in the building — location, system, date, installer. Mandatory for public buildings, special-use, larger properties in Winterberg.

Have your seals checked for Winterberg.

Call us — we take over the seal stock in Winterberg and continue it.

Call+49 2861 8114387