Fire-stop penetration seals in Rheinberg

Sealing what needs to be sealed in Rheinberg and Kreis Wesel. Cable seals, pipe stops, combined penetrations. Soft, hard or mortar seals.

Wall · ceilingS30 · S60 · S90With penetration plan
Rheinberg

What a penetration seal achieves.

Penetration seals are approved closures of wall and ceiling openings. They prevent fire and smoke spread for the same duration the wall itself is rated for — 30, 60 or 90 minutes. Without a seal, every cable, pipe or duct that crosses the wall becomes a direct path for flames and smoke.

Penetration systems for Rheinberg.

We combine Promat, Hilti and Würth — system-open, brand-neutral in Rheinberg.

  1. 01

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables.

  2. 02

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan.

  3. 03

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution. Specified per approval in Rheinberg.

  4. 04

    Cable seal in wall

    Classic in Rheinberg stock: cables through F30/F90 wall, mineral wool with coating or board with collars. Specified per approval in Rheinberg.

  5. 05

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line.

  6. 06

    Stock documentation

    Take over multi-brand stock in Rheinberg, consolidate in the penetration plan, prepare for consultant sign-off.

Where we install seals in Rheinberg.

Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus. Standard scope in Rheinberg.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Rheinberg.
Duct lines
Fire dampers, duct seals — schools, care, offices in Rheinberg. Standard scope in Rheinberg.
Stock survey
Take over multi-brand stock in Rheinberg, inspect, transfer into penetration plan, prepare for authorities. Standard scope in Rheinberg.
Cable trays
Tray penetrations with box seals or aggregate seals. Standard scope in Rheinberg.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Rheinberg. Standard scope in Rheinberg.

Standards.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Rheinberg buildings.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Rheinberg.

What penetration seals cost in Rheinberg.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Rheinberg

Fixed offer after walkthrough in Rheinberg.

Fire stops in Rheinberg — FAQ.

  • A penetration plan documents every seal in the building — location, system, date, installer. Mandatory for public buildings, special-use, larger properties in Rheinberg.

Have your seals checked for Rheinberg.

Walkthrough in Rheinberg → defect list → fixed offer.

Call+49 2861 8114387