Fire-stop penetration seals in Rees

Cable and pipe penetrations for walls and ceilings in Rees — approved, tested, documented. Promat, Hilti, Würth · S30 to S90 · existing stock, new build, retrofit.

Walkthrough in ReesDefect list includedFixed offer
Rees

What a penetration seal achieves.

An F90-rated wall in Rees loses its function the second a cable, pipe or duct passes through it unsealed. Only the approved penetration seal restores that fire resistance — and only if the system used matches the wall construction.

Penetration systems for Rees.

We combine Promat, Hilti and Würth — system-open, brand-neutral in Rees.

  1. 01

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables. Documented in the property log in Rees.

  2. 02

    Stock documentation

    Take over multi-brand stock in Rees, consolidate in the penetration plan, prepare for consultant sign-off. Documented in the property log in Rees.

  3. 03

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution. Specified per approval in Rees.

  4. 04

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line.

  5. 05

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan. Specified per approval in Rees.

  6. 06

    Cable seal in wall

    Classic in Rees stock: cables through F30/F90 wall, mineral wool with coating or board with collars. Documented in the property log in Rees.

Where we install seals in Rees.

Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Rees.
Cable trays
Tray penetrations with box seals or aggregate seals.
Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus. Standard scope in Rees.
Duct lines
Fire dampers, duct seals — schools, care, offices in Rees. Standard scope in Rees.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Rees. Standard scope in Rees.
Stock survey
Take over multi-brand stock in Rees, inspect, transfer into penetration plan, prepare for authorities.

Standards.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Rees buildings.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Rees.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

What penetration seals cost in Rees.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Rees

Fixed offer after walkthrough in Rees.

Fire stops in Rees — FAQ.

  • Yes — as long as each position has an approval and the documentation is consistent. We take over stock brand-neutrally.

Have your seals checked for Rees.

Call us — we take over the seal stock in Rees and continue it.

Call+49 2861 8114387