Fire-stop penetration seals in Odenthal

Odenthal needs penetration seals that hold the fire-compartment boundary, pass the inspection, get signed off.

Promat · Hilti · WürthExisting & newAudit-ready documentation
Odenthal

What a penetration seal achieves.

The right system depends on context. Soft seals handle most wall penetrations in Odenthal stock; mortar systems go in for higher loads. Combined cable+pipe penetrations need a system that's documented in the penetration plan.

Penetration systems for Odenthal.

The system depends on opening size, occupancy density and wall type.

  1. 01

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution.

  2. 02

    Cable seal in wall

    Classic in Odenthal stock: cables through F30/F90 wall, mineral wool with coating or board with collars.

  3. 03

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan.

  4. 04

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables.

  5. 05

    Stock documentation

    Take over multi-brand stock in Odenthal, consolidate in the penetration plan, prepare for consultant sign-off.

  6. 06

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line. Audit-ready in Odenthal.

Where we install seals in Odenthal.

Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus. Standard scope in Odenthal.
Duct lines
Fire dampers, duct seals — schools, care, offices in Odenthal. Standard scope in Odenthal.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Odenthal.
Stock survey
Take over multi-brand stock in Odenthal, inspect, transfer into penetration plan, prepare for authorities. Standard scope in Odenthal.
Cable trays
Tray penetrations with box seals or aggregate seals.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Odenthal. Standard scope in Odenthal.

Standards.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Odenthal.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Odenthal buildings.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

What penetration seals cost in Odenthal.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Odenthal

Fixed offer after walkthrough in Odenthal.

Fire stops in Odenthal — FAQ.

  • A penetration plan documents every seal in the building — location, system, date, installer. Mandatory for public buildings, special-use, larger properties in Odenthal.

Have your seals checked for Odenthal.

Walkthrough in Odenthal → defect list → fixed offer.

Call+49 2861 8114387