Fire-protective claddings in Leopoldshöhe

Cladding steelwork, lining ventilation ducts, retrofitting load-bearing structures in Leopoldshöhe. Boards, coatings, mineral-wool systems.

Request survey+49 2861 8114387
Promatect · Knauf · HiltiSurvey in LeopoldshöheFixed offer
Leopoldshöhe

What fire cladding does.

System selection in Leopoldshöhe depends on the bauteil and the visibility. Conservation-grade structures often get spray-applied systems — they meet F-rating without altering geometry. industrial halls use board cladding for cost and speed.

Cladding types for Leopoldshöhe.

What we install in Leopoldshöhe depends on the structure, appearance and construction phase.

  1. 01

    Shaft cladding

    Lift shafts or service shafts — F90 outside, F30 inside, per concept in Leopoldshöhe. Specified per approval in Leopoldshöhe.

  2. 02

    Timber beam protection

    F30/F60 cladding for existing ceilings — for top-ups, renovation, stock protection in Leopoldshöhe.

  3. 03

    Duct cladding

    Promatect-L or equivalent — fully enclosing the duct, per approval, in Leopoldshöhe industrial settings.

  4. 04

    Fire-protective coating

    Intumescent coating — for visible steelwork, where boards would interfere visually. Specified per approval in Leopoldshöhe.

  5. 05

    Sprayed plaster

    Sprayable, for large-area load-bearing structures in industrial halls where appearance is secondary.

  6. 06

    Steel beam F30/F90

    Board cladding with Promatect or Knauf — three-sided or four-sided box around the beam. Audit-ready in Leopoldshöhe.

Where we cladding in Leopoldshöhe.

Stairwell structure
Steel staircases with F30 cladding — in stock, new build, as renovation measure. Standard scope in Leopoldshöhe.
Service shaft
Heating, sewage, ventilation shaft — F90 cladding with inspection openings.
Duct lines
Ventilation ducts in school, care, office buildings in Leopoldshöhe — F90 cladding all-round. Standard scope in Leopoldshöhe.
Lift shaft
F90 shaft wall with cladding — for stock renovation, top-up storeys, new build in Leopoldshöhe. Standard scope in Leopoldshöhe.
Hall load-bearing
Steel beams in logistics and production halls in Leopoldshöhe — F30 to F90 per concept, audit-ready.
Timber ceiling
Stock cladding for timber-beam ceilings — F30/F60 underside in Leopoldshöhe stock.

Standards.

  • DIN 4102-4
    Components under fire

    F30/F90/F120 classification — the foundation, building-authority recognised, in stock and new build.

  • abZ
    Building-authority approval

    Every cladding with approval and conformity declaration.

  • EN 13501-2
    EU classification

    EI ratings for claddings — parallel to DIN, EU-recognised.

  • MLAR
    Cable line directive

    Governs cladding of cable routes — alongside penetration plans, in stock documentation, in new build.

What fire claddings cost in Leopoldshöhe.

Heavily dependent on component and area — fixed price after survey.

  • from €60/m
    Steel beam F30 board claddingPer linear metre, three-sided
  • €120 – €250/m²
    Duct cladding F90All-round, in line
  • from €80/m²
    Shaft wall F90Lift shaft / service
  • Fixed price
    Timber-beam upgradeLump-sum after walkthrough in Leopoldshöhe
  • On request
    Fire-protective coatingPer m² visible area, intumescent

Fixed offer after survey in Leopoldshöhe.

Claddings in Leopoldshöhe — FAQ.

  • Decades — as long as the component stands, until mechanical damage. Inspection every 5 years recommended.

Plan claddings for Leopoldshöhe.

Survey in Leopoldshöhe → board order → install. Documentation audit-ready.

Call+49 2861 8114387