Fire-protective claddings in Horstmar

Fire claddings for steel beams, timber elements and ventilation ducts in Horstmar. F30, F90 and higher — approved Promatect, Knauf fire systems.

Request survey+49 2861 8114387
Existing & newBrand-openOn site weekdays
Horstmar

What fire cladding does.

Fire claddings are board constructions that protect ventilation ducts from load loss for 30 to 120 minutes. The cladding turns an combustible timber into an F30/F90-compliant component.

Cladding types for Horstmar.

What we install in Horstmar depends on the structure, appearance and construction phase.

  1. 01

    Shaft cladding

    Lift shafts or service shafts — F90 outside, F30 inside, per concept in Horstmar.

  2. 02

    Timber beam protection

    F30/F60 cladding for existing ceilings — for top-ups, renovation, stock protection in Horstmar.

  3. 03

    Steel beam F30/F90

    Board cladding with Promatect or Knauf — three-sided or four-sided box around the beam. Specified per approval in Horstmar.

  4. 04

    Fire-protective coating

    Intumescent coating — for visible steelwork, where boards would interfere visually. Specified per approval in Horstmar.

  5. 05

    Duct cladding

    Promatect-L or equivalent — fully enclosing the duct, per approval, in Horstmar industrial settings. Specified per approval in Horstmar.

  6. 06

    Sprayed plaster

    Sprayable, for large-area load-bearing structures in industrial halls where appearance is secondary.

Where we cladding in Horstmar.

Timber ceiling
Stock cladding for timber-beam ceilings — F30/F60 underside in Horstmar stock. Standard scope in Horstmar.
Duct lines
Ventilation ducts in school, care, office buildings in Horstmar — F90 cladding all-round. Standard scope in Horstmar.
Lift shaft
F90 shaft wall with cladding — for stock renovation, top-up storeys, new build in Horstmar. Standard scope in Horstmar.
Hall load-bearing
Steel beams in logistics and production halls in Horstmar — F30 to F90 per concept, audit-ready.
Stairwell structure
Steel staircases with F30 cladding — in stock, new build, as renovation measure.
Service shaft
Heating, sewage, ventilation shaft — F90 cladding with inspection openings.

Standards.

  • DIN 4102-4
    Components under fire

    F30/F90/F120 classification — the foundation, building-authority recognised, in stock and new build.

  • MLAR
    Cable line directive

    Governs cladding of cable routes — alongside penetration plans, in stock documentation, in new build.

  • EN 13501-2
    EU classification

    EI ratings for claddings — parallel to DIN, EU-recognised.

  • abZ
    Building-authority approval

    Every cladding with approval and conformity declaration.

What fire claddings cost in Horstmar.

Heavily dependent on component and area — fixed price after survey.

  • from €60/m
    Steel beam F30 board claddingPer linear metre, three-sided
  • €120 – €250/m²
    Duct cladding F90All-round, in line
  • from €80/m²
    Shaft wall F90Lift shaft / service
  • Fixed price
    Timber-beam upgradeLump-sum after walkthrough in Horstmar
  • On request
    Fire-protective coatingPer m² visible area, intumescent

Fixed offer after survey in Horstmar.

Claddings in Horstmar — FAQ.

  • Decades — as long as the component stands, until mechanical damage. Inspection every 5 years recommended.

Plan claddings for Horstmar.

Survey in Horstmar → board order → install. Documentation audit-ready.

Call+49 2861 8114387