Fire-stop penetration seals in Havixbeck

Sealing what needs to be sealed in Havixbeck and Kreis Coesfeld. Cable seals, pipe stops, combined penetrations. Soft, hard or mortar seals.

Promat · Hilti · WürthExisting & newAudit-ready documentation
Havixbeck

What a penetration seal achieves.

The right system depends on context. Modular block sets handle most wall penetrations in Havixbeck stock; hard seals go in for when frequent re-cabling is expected. Combined cable+pipe penetrations need a system that's documented in the penetration plan.

Penetration systems for Havixbeck.

The system depends on opening size, occupancy density and wall type.

  1. 01

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan. Specified per approval in Havixbeck.

  2. 02

    Stock documentation

    Take over multi-brand stock in Havixbeck, consolidate in the penetration plan, prepare for consultant sign-off.

  3. 03

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line.

  4. 04

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables. Specified per approval in Havixbeck.

  5. 05

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution.

  6. 06

    Cable seal in wall

    Classic in Havixbeck stock: cables through F30/F90 wall, mineral wool with coating or board with collars.

Where we install seals in Havixbeck.

Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Havixbeck.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Havixbeck.
Stock survey
Take over multi-brand stock in Havixbeck, inspect, transfer into penetration plan, prepare for authorities. Standard scope in Havixbeck.
Cable trays
Tray penetrations with box seals or aggregate seals. Standard scope in Havixbeck.
Duct lines
Fire dampers, duct seals — schools, care, offices in Havixbeck. Standard scope in Havixbeck.

Standards.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Havixbeck buildings.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Havixbeck.

What penetration seals cost in Havixbeck.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Havixbeck

Fixed offer after walkthrough in Havixbeck.

Fire stops in Havixbeck — FAQ.

  • At least annually as part of maintenance — and after every cable/pipe change. Maintenance log mandatory in Havixbeck.

Have your seals checked for Havixbeck.

Call us — we take over the seal stock in Havixbeck and continue it.

Call+49 2861 8114387