Fire-stop penetration seals in Altenberge

Wall and ceiling penetrations in Altenberge sealed audit-ready, installed to approval, tracked in penetration plans for the consultant's sign-off.

Request walkthrough+49 2861 8114387
Wall · ceilingS30 · S60 · S90With penetration plan
Altenberge

What a penetration seal achieves.

An F90-rated wall in Altenberge loses its function the instant a cable, pipe or duct passes through it unsealed. Only the systemgeprüfte penetration seal restores that fire resistance — and only if the system used matches the opening size.

Penetration systems for Altenberge.

We combine Promat, Hilti and Würth — system-open, brand-neutral in Altenberge.

  1. 01

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line.

  2. 02

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables. Documented in the property log in Altenberge.

  3. 03

    Cable seal in wall

    Classic in Altenberge stock: cables through F30/F90 wall, mineral wool with coating or board with collars. Documented in the property log in Altenberge.

  4. 04

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan.

  5. 05

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution.

  6. 06

    Stock documentation

    Take over multi-brand stock in Altenberge, consolidate in the penetration plan, prepare for consultant sign-off. Specified per approval in Altenberge.

Where we install seals in Altenberge.

Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Altenberge.
Duct lines
Fire dampers, duct seals — schools, care, offices in Altenberge. Standard scope in Altenberge.
Stock survey
Take over multi-brand stock in Altenberge, inspect, transfer into penetration plan, prepare for authorities.
Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus. Standard scope in Altenberge.
Cable trays
Tray penetrations with box seals or aggregate seals.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Altenberge. Standard scope in Altenberge.

Standards.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Altenberge.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Altenberge buildings.

What penetration seals cost in Altenberge.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Altenberge

Fixed offer after walkthrough in Altenberge.

Fire stops in Altenberge — FAQ.

  • A penetration plan documents every seal in the building — location, system, date, installer. Mandatory for public buildings, special-use, larger properties in Altenberge.

Have your seals checked for Altenberge.

Call us — we take over the seal stock in Altenberge and continue it.

Call+49 2861 8114387