Fire-protective claddings in Ense

Ense has steel halls, ventilation runs and load-bearing structures that must keep their function under fire. We install, renovate, document audit-ready.

Existing & newBrand-openOn site weekdays
Ense

What fire cladding does.

System selection in Ense depends on the bauteil and the visibility. Architectural beams often get intumescent coatings — they meet F-rating without altering geometry. Hidden beams use Promatect plates for cost and speed.

Cladding types for Ense.

What we install in Ense depends on the structure, appearance and construction phase.

  1. 01

    Shaft cladding

    Lift shafts or service shafts — F90 outside, F30 inside, per concept in Ense.

  2. 02

    Sprayed plaster

    Sprayable, for large-area load-bearing structures in industrial halls where appearance is secondary. Documented in the property log in Ense.

  3. 03

    Duct cladding

    Promatect-L or equivalent — fully enclosing the duct, per approval, in Ense industrial settings.

  4. 04

    Steel beam F30/F90

    Board cladding with Promatect or Knauf — three-sided or four-sided box around the beam. Specified per approval in Ense.

  5. 05

    Timber beam protection

    F30/F60 cladding for existing ceilings — for top-ups, renovation, stock protection in Ense. Audit-ready in Ense.

  6. 06

    Fire-protective coating

    Intumescent coating — for visible steelwork, where boards would interfere visually.

Where we cladding in Ense.

Timber ceiling
Stock cladding for timber-beam ceilings — F30/F60 underside in Ense stock.
Duct lines
Ventilation ducts in school, care, office buildings in Ense — F90 cladding all-round.
Service shaft
Heating, sewage, ventilation shaft — F90 cladding with inspection openings. Standard scope in Ense.
Lift shaft
F90 shaft wall with cladding — for stock renovation, top-up storeys, new build in Ense. Standard scope in Ense.
Stairwell structure
Steel staircases with F30 cladding — in stock, new build, as renovation measure. Standard scope in Ense.
Hall load-bearing
Steel beams in logistics and production halls in Ense — F30 to F90 per concept, audit-ready. Standard scope in Ense.

Standards.

  • MLAR
    Cable line directive

    Governs cladding of cable routes — alongside penetration plans, in stock documentation, in new build.

  • EN 13501-2
    EU classification

    EI ratings for claddings — parallel to DIN, EU-recognised.

  • DIN 4102-4
    Components under fire

    F30/F90/F120 classification — the foundation, building-authority recognised, in stock and new build.

  • abZ
    Building-authority approval

    Every cladding with approval and conformity declaration.

What fire claddings cost in Ense.

Heavily dependent on component and area — fixed price after survey.

  • from €60/m
    Steel beam F30 board claddingPer linear metre, three-sided
  • €120 – €250/m²
    Duct cladding F90All-round, in line
  • from €80/m²
    Shaft wall F90Lift shaft / service
  • Fixed price
    Timber-beam upgradeLump-sum after walkthrough in Ense
  • On request
    Fire-protective coatingPer m² visible area, intumescent

Fixed offer after survey in Ense.

Claddings in Ense — FAQ.

  • Decades — as long as the component stands, until mechanical damage. Inspection every 5 years recommended.

Plan claddings for Ense.

Survey in Ense → board order → install. Documentation audit-ready.

Call+49 2861 8114387