Fire-stop penetration seals in Brakel

Wall and ceiling penetrations in Brakel sealed audit-ready, installed to approval, tracked in penetration plans for the consultant's sign-off.

Promat · Hilti · WürthExisting & newAudit-ready documentation
Brakel

What a penetration seal achieves.

An F90-rated wall in Brakel loses its function the moment a cable, pipe or duct passes through it unprotected. Only the tested penetration seal restores that fire resistance — and only if the system used matches the cable density.

Penetration systems for Brakel.

We combine Promat, Hilti and Würth — system-open, brand-neutral in Brakel.

  1. 01

    Stock documentation

    Take over multi-brand stock in Brakel, consolidate in the penetration plan, prepare for consultant sign-off. Specified per approval in Brakel.

  2. 02

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables.

  3. 03

    Cable seal in wall

    Classic in Brakel stock: cables through F30/F90 wall, mineral wool with coating or board with collars.

  4. 04

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line.

  5. 05

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan. Specified per approval in Brakel.

  6. 06

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution. Documented in the property log in Brakel.

Where we install seals in Brakel.

Cable trays
Tray penetrations with box seals or aggregate seals.
Duct lines
Fire dampers, duct seals — schools, care, offices in Brakel.
Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus. Standard scope in Brakel.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Brakel. Standard scope in Brakel.
Stock survey
Take over multi-brand stock in Brakel, inspect, transfer into penetration plan, prepare for authorities. Standard scope in Brakel.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Brakel. Standard scope in Brakel.

Standards.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Brakel buildings.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Brakel.

What penetration seals cost in Brakel.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Brakel

Fixed offer after walkthrough in Brakel.

Fire stops in Brakel — FAQ.

  • Yes — open seal, add cable, reseal. Standard service in Brakel.

Have your seals checked for Brakel.

Walkthrough in Brakel → defect list → fixed offer.

Call+49 2861 8114387