Fire-stop penetration seals in Beverungen

Wall and ceiling penetrations in Beverungen sealed audit-ready, installed to approval, tracked in penetration plans for the consultant's sign-off.

Request walkthrough+49 2861 8114387
Walkthrough in BeverungenDefect list includedFixed offer
Beverungen

What a penetration seal achieves.

The right system depends on context. Soft seals handle most wall penetrations in Beverungen stock; fire boards go in for higher loads. Combined cable+pipe penetrations need a system that's approved for both.

Penetration systems for Beverungen.

The system depends on opening size, occupancy density and wall type.

  1. 01

    Cable seal in wall

    Classic in Beverungen stock: cables through F30/F90 wall, mineral wool with coating or board with collars.

  2. 02

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line. Documented in the property log in Beverungen.

  3. 03

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution. Audit-ready in Beverungen.

  4. 04

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan.

  5. 05

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables.

  6. 06

    Stock documentation

    Take over multi-brand stock in Beverungen, consolidate in the penetration plan, prepare for consultant sign-off.

Where we install seals in Beverungen.

Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Beverungen.
Duct lines
Fire dampers, duct seals — schools, care, offices in Beverungen.
Stock survey
Take over multi-brand stock in Beverungen, inspect, transfer into penetration plan, prepare for authorities.
Cable trays
Tray penetrations with box seals or aggregate seals.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Beverungen. Standard scope in Beverungen.

Standards.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Beverungen.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Beverungen buildings.

What penetration seals cost in Beverungen.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Beverungen