Logistics halls
Rooflight-band NSHEV across the hall length, coordinated with high-bay racking and fire compartments.
We accompany your project from early design through to handover. Sizing calculation, tender text, supply, installation and instruction — code-compliant in accordance with the applicable proofs of usability, with full documentation for handover and subsequent operation.

In a new build, the economics of a SHEV are decided early — often before the roof structure stands. The earlier we are involved in planning, the better opening areas, device position, control cable routing and supply-air following can be coordinated with the building structure, roof drainage and building services. We work along the HOAI service phases: phases 2 / 3 bring advice and sizing calculation, phase 5 detailed planning, phase 6 tender text and bill of quantities, phase 8 supply, installation, commissioning and handover. Sizing basis is applicable proof of usability (natural) or -5 (powered) with object-specific geometry and assumed fire load. The result is the required aerodynamic effective area, from which number, size and layout of the NSHEV follow. For PSHEV we calculate the required volumetric flow, the air ducting and the fan temperature class. Handover takes place together with the fire safety expert or the inspection expert under PrüfVO NRW — with functional evidence of all components.
Which variant fits depends on the installation context, the existing building and the fire-protection concept — we advise per project.
Aerodynamic effective area, volumetric flow, supply-air concept — as evidence for building approval.
Positioning, cable routes, control panel, detector and manual call point planning.
Bill of quantities per VOB/C or as functional tender.
CE- and applicable proof of usability-compliant, with Declaration of Performance and approval evidence.
Installation by certified fitters, incl. control cables and panel.
Functional test, protocol, operator briefing, documentation.
Prices are indicative without planning fees and VAT. Binding after sizing calculation and detailed planning.
We cover every typical building type — from residential to industrial complexes with hundreds of components per site.
Rooflight-band NSHEV across the hall length, coordinated with high-bay racking and fire compartments.
NSHEV plus powered extraction in fire-load-intensive areas.
Stairwell SHEV, atrium extraction, possibly pressurised smoke protection.
Ceiling outlet, supply air via facade, smoke curtains for containment.
Powered CO ventilation plus extraction per Garage Ordinance.
Stairwell extraction, SHEV via rooflight dome, smoke detectors with FDA linkage.
Natural smoke exhaust — calculation, verification, layout.
PSHEV — volumetric flow, air ducting, fans.
Minimum requirements for NSHEV, fans, pressurisation.
Performance description for insulation and fire protection works.
When and where a SHEV is legally required.
Each phase with clear milestones — no schedule surprises and no cost blocks in change orders.
Sizing, installation, handover — no interface between planner and contractor.
We plug into HOAI service phases 2 to 8 — clean invoicing, clean documentation.
We select the system that fits technically — not the one that maximises our margin.
With an inspection expert under PrüfVO NRW — up to signature on the handover protocol.
Site inspection, occupancy, fire protection concept, initial feasibility.
Calculation in accordance with the applicable proofs of usability with device proposal and variant comparison.
Layout plans, cable routes, interfaces to facade, roof, electrical.
Just-in-time to site, interim storage by arrangement.
Assembly, wiring, commissioning — coordinated with construction progress.
Inspection with expert, operator briefing, handover of documentation.
Send us plans, occupancy description and fire protection concept (or draft). We respond within one business day with an initial assessment and a price frame.