Fire-stop penetration seals in Stemwede

Cable and pipe penetrations for walls and ceilings in Stemwede — approved, tested, documented. Promat, Hilti, Würth · S30 to S90 · existing stock, new build, retrofit.

Wall · ceilingS30 · S60 · S90With penetration plan
Stemwede

What a penetration seal achieves.

The right system depends on context. Modular block sets handle most wall penetrations in Stemwede stock; fire boards go in for higher loads. Combined cable+pipe penetrations need a system that's listed in the manufacturer's range.

Penetration systems for Stemwede.

The system depends on opening size, occupancy density and wall type.

  1. 01

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution. Audit-ready in Stemwede.

  2. 02

    Cable seal in wall

    Classic in Stemwede stock: cables through F30/F90 wall, mineral wool with coating or board with collars. Specified per approval in Stemwede.

  3. 03

    Stock documentation

    Take over multi-brand stock in Stemwede, consolidate in the penetration plan, prepare for consultant sign-off. Specified per approval in Stemwede.

  4. 04

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables. Audit-ready in Stemwede.

  5. 05

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan. Documented in the property log in Stemwede.

  6. 06

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line. Documented in the property log in Stemwede.

Where we install seals in Stemwede.

Cable trays
Tray penetrations with box seals or aggregate seals. Standard scope in Stemwede.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Stemwede.
Stock survey
Take over multi-brand stock in Stemwede, inspect, transfer into penetration plan, prepare for authorities. Standard scope in Stemwede.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Stemwede. Standard scope in Stemwede.
Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus. Standard scope in Stemwede.
Duct lines
Fire dampers, duct seals — schools, care, offices in Stemwede.

Standards.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Stemwede buildings.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Stemwede.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

What penetration seals cost in Stemwede.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Stemwede

Fixed offer after walkthrough in Stemwede.

Fire stops in Stemwede — FAQ.

  • A penetration plan documents every seal in the building — location, system, date, installer. Mandatory for public buildings, special-use, larger properties in Stemwede.