Fire-stop penetration seals in Selfkant

Cable and pipe penetrations for walls and ceilings in Selfkant — approved, tested, documented. Promat, Hilti, Würth · S30 to S90 · existing stock, new build, retrofit.

Wall · ceilingS30 · S60 · S90With penetration plan
Selfkant

What a penetration seal achieves.

Penetration seals are DIN-validated closures of wall and ceiling openings. They prevent fire and smoke spread for the same duration the wall itself is rated for — 30, 60 or 90 minutes. Without a seal, every cable, pipe or duct that crosses the wall becomes a direct path for flames and smoke.

Penetration systems for Selfkant.

The system depends on opening size, occupancy density and wall type.

  1. 01

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan.

  2. 02

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution. Documented in the property log in Selfkant.

  3. 03

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables.

  4. 04

    Cable seal in wall

    Classic in Selfkant stock: cables through F30/F90 wall, mineral wool with coating or board with collars.

  5. 05

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line. Audit-ready in Selfkant.

  6. 06

    Stock documentation

    Take over multi-brand stock in Selfkant, consolidate in the penetration plan, prepare for consultant sign-off.

Where we install seals in Selfkant.

Cable trays
Tray penetrations with box seals or aggregate seals. Standard scope in Selfkant.
Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus.
Stock survey
Take over multi-brand stock in Selfkant, inspect, transfer into penetration plan, prepare for authorities. Standard scope in Selfkant.
Duct lines
Fire dampers, duct seals — schools, care, offices in Selfkant.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Selfkant.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Selfkant.

Standards.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Selfkant buildings.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Selfkant.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

What penetration seals cost in Selfkant.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Selfkant

Fixed offer after walkthrough in Selfkant.

Fire stops in Selfkant — FAQ.

  • Yes — open seal, add cable, reseal. Standard service in Selfkant.

Have your seals checked for Selfkant.

Call us — we take over the seal stock in Selfkant and continue it.