Fire-stop penetration seals in Sankt Augustin

Sankt Augustin needs penetration seals that hold the fire-compartment boundary, pass the inspection, get signed off.

Request walkthrough+49 2861 8114387
Promat · Hilti · WürthExisting & newAudit-ready documentation
Sankt Augustin

What a penetration seal achieves.

The right system depends on context. Modular block sets handle most wall penetrations in Sankt Augustin stock; mortar systems go in for higher loads. Combined cable+pipe penetrations need a system that's documented in the penetration plan.

Penetration systems for Sankt Augustin.

The system depends on opening size, occupancy density and wall type.

  1. 01

    Stock documentation

    Take over multi-brand stock in Sankt Augustin, consolidate in the penetration plan, prepare for consultant sign-off. Specified per approval in Sankt Augustin.

  2. 02

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line.

  3. 03

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables.

  4. 04

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution.

  5. 05

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan.

  6. 06

    Cable seal in wall

    Classic in Sankt Augustin stock: cables through F30/F90 wall, mineral wool with coating or board with collars.

Where we install seals in Sankt Augustin.

Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Sankt Augustin.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Sankt Augustin. Standard scope in Sankt Augustin.
Cable trays
Tray penetrations with box seals or aggregate seals. Standard scope in Sankt Augustin.
Stock survey
Take over multi-brand stock in Sankt Augustin, inspect, transfer into penetration plan, prepare for authorities.
Duct lines
Fire dampers, duct seals — schools, care, offices in Sankt Augustin. Standard scope in Sankt Augustin.
Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus.

Standards.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Sankt Augustin buildings.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Sankt Augustin.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

What penetration seals cost in Sankt Augustin.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Sankt Augustin

Fixed offer after walkthrough in Sankt Augustin.

Fire stops in Sankt Augustin — FAQ.

  • At least annually as part of maintenance — and after every cable/pipe change. Maintenance log mandatory in Sankt Augustin.

Have your seals checked for Sankt Augustin.

Call us — we take over the seal stock in Sankt Augustin and continue it.

Call+49 2861 8114387