What a penetration seal achieves.

Penetration seals are approved closures of wall and ceiling openings. They prevent fire and smoke spread for the same duration the wall itself is rated for — 30, 60 or 90 minutes. Without a seal, every cable, pipe or duct that crosses the wall becomes a weak point for flames and smoke.

Penetration systems for Olpe.

The system depends on opening size, occupancy density and wall type.

  1. 01

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables.

  2. 02

    Stock documentation

    Take over multi-brand stock in Olpe, consolidate in the penetration plan, prepare for consultant sign-off. Audit-ready in Olpe.

  3. 03

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line. Specified per approval in Olpe.

  4. 04

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution. Audit-ready in Olpe.

  5. 05

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan.

  6. 06

    Cable seal in wall

    Classic in Olpe stock: cables through F30/F90 wall, mineral wool with coating or board with collars.

Where we install seals in Olpe.

Cable trays
Tray penetrations with box seals or aggregate seals.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Olpe. Standard scope in Olpe.
Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus. Standard scope in Olpe.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Olpe. Standard scope in Olpe.
Stock survey
Take over multi-brand stock in Olpe, inspect, transfer into penetration plan, prepare for authorities.
Duct lines
Fire dampers, duct seals — schools, care, offices in Olpe.

Standards.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Olpe.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Olpe buildings.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

What penetration seals cost in Olpe.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Olpe

Fixed offer after walkthrough in Olpe.

Fire stops in Olpe — FAQ.

  • Yes — as long as each position has an approval and the documentation is consistent. We take over stock brand-neutrally.