Fire-stop penetration seals in Nideggen

Cable and pipe penetrations for walls and ceilings in Nideggen — approved, tested, documented. Promat, Hilti, Würth · S30 to S90 · existing stock, new build, retrofit.

Promat · Hilti · WürthExisting & newAudit-ready documentation
Nideggen

What a penetration seal achieves.

Every wall penetration in Nideggen that crosses a fire-compartment boundary needs documentation: photo of the closed seal. Consultants check this every year. Insurers reference it after a loss. A missing seal is the kind of finding that delays sign-off.

Penetration systems for Nideggen.

We combine Promat, Hilti and Würth — system-open, brand-neutral in Nideggen.

  1. 01

    Cable seal in wall

    Classic in Nideggen stock: cables through F30/F90 wall, mineral wool with coating or board with collars. Audit-ready in Nideggen.

  2. 02

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution.

  3. 03

    Stock documentation

    Take over multi-brand stock in Nideggen, consolidate in the penetration plan, prepare for consultant sign-off. Specified per approval in Nideggen.

  4. 04

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan.

  5. 05

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line.

  6. 06

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables. Specified per approval in Nideggen.

Where we install seals in Nideggen.

Cable trays
Tray penetrations with box seals or aggregate seals.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Nideggen. Standard scope in Nideggen.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Nideggen.
Duct lines
Fire dampers, duct seals — schools, care, offices in Nideggen.
Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus.
Stock survey
Take over multi-brand stock in Nideggen, inspect, transfer into penetration plan, prepare for authorities.

Standards.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Nideggen.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Nideggen buildings.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

What penetration seals cost in Nideggen.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Nideggen

Fixed offer after walkthrough in Nideggen.

Fire stops in Nideggen — FAQ.

  • Yes — as long as each position has an approval and the documentation is consistent. We take over stock brand-neutrally.

Have your seals checked for Nideggen.

Call us — we take over the seal stock in Nideggen and continue it.