Fire-stop penetration seals in Mönchengladbach

Sealing what needs to be sealed in Mönchengladbach and Kreis Mönchengladbach, Stadt. Cable seals, pipe stops, combined penetrations. Soft, hard or mortar seals.

Request walkthrough+49 2861 8114387
Wall · ceilingS30 · S60 · S90With penetration plan
Mönchengladbach

What a penetration seal achieves.

An F90-rated wall in Mönchengladbach loses its function the second a cable, pipe or duct passes through it unprotected. Only the systemgeprüfte penetration seal restores that fire resistance — and only if the system used matches the pipe type.

Penetration systems for Mönchengladbach.

We combine Promat, Hilti and Würth — system-open, brand-neutral in Mönchengladbach.

  1. 01

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution.

  2. 02

    Cable seal in wall

    Classic in Mönchengladbach stock: cables through F30/F90 wall, mineral wool with coating or board with collars.

  3. 03

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables.

  4. 04

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line. Specified per approval in Mönchengladbach.

  5. 05

    Stock documentation

    Take over multi-brand stock in Mönchengladbach, consolidate in the penetration plan, prepare for consultant sign-off.

  6. 06

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan. Documented in the property log in Mönchengladbach.

Where we install seals in Mönchengladbach.

Cable trays
Tray penetrations with box seals or aggregate seals. Standard scope in Mönchengladbach.
Duct lines
Fire dampers, duct seals — schools, care, offices in Mönchengladbach. Standard scope in Mönchengladbach.
Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus. Standard scope in Mönchengladbach.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Mönchengladbach.
Stock survey
Take over multi-brand stock in Mönchengladbach, inspect, transfer into penetration plan, prepare for authorities. Standard scope in Mönchengladbach.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Mönchengladbach. Standard scope in Mönchengladbach.

Standards.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Mönchengladbach.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Mönchengladbach buildings.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

What penetration seals cost in Mönchengladbach.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Mönchengladbach

Fixed offer after walkthrough in Mönchengladbach.

Fire stops in Mönchengladbach — FAQ.

  • Yes — as long as each position has an approval and the documentation is consistent. We take over stock brand-neutrally.

Have your seals checked for Mönchengladbach.

Walkthrough in Mönchengladbach → defect list → fixed offer.

Call+49 2861 8114387