Fire-stop penetration seals in Langenberg

Wall and ceiling penetrations in Langenberg sealed audit-ready, installed to approval, tracked in penetration plans for the consultant's sign-off.

Request walkthrough+49 2861 8114387
Wall · ceilingS30 · S60 · S90With penetration plan
Langenberg

What a penetration seal achieves.

An F90-rated wall in Langenberg loses its function the second a cable, pipe or duct passes through it unprotected. Only the approved penetration seal restores that fire resistance — and only if the system used matches the cable density.

Penetration systems for Langenberg.

The system depends on opening size, occupancy density and wall type.

  1. 01

    Cable seal in wall

    Classic in Langenberg stock: cables through F30/F90 wall, mineral wool with coating or board with collars. Audit-ready in Langenberg.

  2. 02

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution.

  3. 03

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan. Specified per approval in Langenberg.

  4. 04

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line.

  5. 05

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables. Specified per approval in Langenberg.

  6. 06

    Stock documentation

    Take over multi-brand stock in Langenberg, consolidate in the penetration plan, prepare for consultant sign-off. Documented in the property log in Langenberg.

Where we install seals in Langenberg.

Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Langenberg.
Cable trays
Tray penetrations with box seals or aggregate seals. Standard scope in Langenberg.
Stock survey
Take over multi-brand stock in Langenberg, inspect, transfer into penetration plan, prepare for authorities. Standard scope in Langenberg.
Duct lines
Fire dampers, duct seals — schools, care, offices in Langenberg.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Langenberg.

Standards.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Langenberg buildings.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Langenberg.

What penetration seals cost in Langenberg.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Langenberg

Fixed offer after walkthrough in Langenberg.

Fire stops in Langenberg — FAQ.

  • A penetration plan documents every seal in the building — location, system, date, installer. Mandatory for public buildings, special-use, larger properties in Langenberg.

Have your seals checked for Langenberg.

Walkthrough in Langenberg → defect list → fixed offer.

Call+49 2861 8114387