Fire-rated doors in Heek

Whether stairwell closure, apartment entrance, plant room or boiler in Heek: we deliver the right T-rating, choose from twenty-plus model series and align with the fire-protection concept.

T30 / T60 / T90Steel · wood · glassWith maintenance option
Heek

What a fire door has to deliver.

Inspection in Heek is on the maintenance log cycle. The door must close fully, latch without manual help, seal smoke at the threshold, and show no hinge play. We document every position — datasheet — so the maintenance log holds up at the next insurance review.

Fire-door variants for Heek.

Which variant we install in Heek depends on wall situation, fire-protection concept, use and aesthetics.

  1. 01

    Double-leaf

    For wide passageways or representative entrances in Heek. Standing leaf with bolt, active leaf with handle. Documented in the property log in Heek.

  2. 02

    Sliding door

    Wall-parallel — when space, swing or clearance is critical in Heek. Specified per approval in Heek.

  3. 03

    Timber door

    Premium look, T30 standard with T60/T90 on request. First choice for offices, care homes and hotels in Heek. Audit-ready in Heek.

  4. 04

    Glass door

    F30/F90 glass with stainless frame — for foyers, entrances and conference partitions in Heek. Specified per approval in Heek.

  5. 05

    Swing door

    Bidirectional, with floor spring, swing closer or vision panel. For industry, logistics and hospitals in Heek. Documented in the property log in Heek.

  6. 06

    Steel door

    Robust, economic, powder-coated or galvanised. Standard solution for stairwells, industry and underground parking in Heek.

Where fire doors are needed in Heek.

Boiler / transformer
T90 with self-locking — required, state of the art, insurance demand for boiler and transformer rooms in Heek.
Apartment entrance
T30 + RC2 burglary resistance — standard combination in Heek multi-family stock. Audit-ready in Heek.
School / care
T30 with finger-protection and accessible operation for Heek public buildings. Specified per approval in Heek.
Stairwell closure
Main use for T30 in residential — mandatory from the 5th floor, otherwise per concept. Most common installation in Heek. Specified per approval in Heek.
Industry / storage
T30/T60 steel doors with industrial fittings in Heek logistics.
Renovation / retrofit
Replace existing doors when approval lapsed, maintenance shows defects or the concept changed in Heek. Audit-ready in Heek.

Standards and approvals.

  • DIN 4102-5
    Fire resistance components

    Defines T30, T60, T90 — the German classifications for fire doors in Heek.

  • abZ
    Building-authority approval

    Every door we install in Heek carries an approval number and declaration of conformity.

  • EN 13501-2
    European classification

    EI30, EI60, EI90 — the EU classification used in parallel with DIN 4102-5.

  • DIN 18093
    Installation in walls

    Rules for installation, anchoring, sealing — binding and inspection-relevant in Heek.

  • MBO § 35
    Model building code

    Mandates fire-resisting closures in stairwells — applies in NRW.

What a fire door costs in Heek.

Reference figures for Heek — fixed quote after on-site measurement.

  • from €800
    T30 standard steel doorSingle-leaf, no glass, fitted in Heek
  • €1,200 – €2,000
    T30 timber doorVeneered or lacquered, single-leaf
  • €1,800 – €3,500
    T90 steel doorBoiler/transformer, possibly self-locking
  • €2,500 – €4,500
    T30/T90 double-leafFoyers, stairwells, wide passageways
  • from €3,500
    F30/F90 glass doorStainless frame, Pyropanel/Promaglas

All prices indicative for Heek — fixed offer after measurement.

Fire doors in Heek — FAQ.

  • Standard T30: 2–4 hours per position. T90 / special builds up to half a day, including prep work.

Order fire doors for Heek.

Schedule survey in Heek → get fixed quote → fix install date. Three steps, no surprises.