Fire-rated doors in Gescher

Gescher needs doors that hold under fire, pass any closing test and get signed off by the consultant. We install them, maintain them, replace them — approved, tested, documented.

Supply & installDocumentation & maintenanceEmergency Gescher
Gescher

What a fire door has to deliver.

Inspection in Gescher is at every consultant audit. The door must close fully, latch without manual help, seal smoke at the threshold, and show no hinge play. We document every position — installer signature — so the maintenance log holds up at the next change-of-use inspection.

Fire-door variants for Gescher.

We deliver across the full range — steel, wood, glass, stainless — in T30, T60 or T90.

  1. 01

    Swing door

    Bidirectional, with floor spring, swing closer or vision panel. For industry, logistics and hospitals in Gescher. Specified per approval in Gescher.

  2. 02

    Sliding door

    Wall-parallel — when space, swing or clearance is critical in Gescher.

  3. 03

    Double-leaf

    For wide passageways or representative entrances in Gescher. Standing leaf with bolt, active leaf with handle.

  4. 04

    Glass door

    F30/F90 glass with stainless frame — for foyers, entrances and conference partitions in Gescher. Documented in the property log in Gescher.

  5. 05

    Timber door

    Premium look, T30 standard with T60/T90 on request. First choice for offices, care homes and hotels in Gescher. Documented in the property log in Gescher.

  6. 06

    Steel door

    Robust, economic, powder-coated or galvanised. Standard solution for stairwells, industry and underground parking in Gescher.

Where fire doors are needed in Gescher.

Industry / storage
T30/T60 steel doors with industrial fittings in Gescher logistics.
Apartment entrance
T30 + RC2 burglary resistance — standard combination in Gescher multi-family stock. Audit-ready in Gescher.
Boiler / transformer
T90 with self-locking — required, state of the art, insurance demand for boiler and transformer rooms in Gescher.
School / care
T30 with finger-protection and accessible operation for Gescher public buildings. Audit-ready in Gescher.
Renovation / retrofit
Replace existing doors when approval lapsed, maintenance shows defects or the concept changed in Gescher.
Stairwell closure
Main use for T30 in residential — mandatory from the 5th floor, otherwise per concept. Most common installation in Gescher. Specified per approval in Gescher.

Standards and approvals.

  • abZ
    Building-authority approval

    Every door we install in Gescher carries an approval number and declaration of conformity.

  • EN 13501-2
    European classification

    EI30, EI60, EI90 — the EU classification used in parallel with DIN 4102-5.

  • MBO § 35
    Model building code

    Mandates fire-resisting closures in stairwells — applies in NRW.

  • DIN 18093
    Installation in walls

    Rules for installation, anchoring, sealing — binding and inspection-relevant in Gescher.

  • DIN 4102-5
    Fire resistance components

    Defines T30, T60, T90 — the German classifications for fire doors in Gescher.

What a fire door costs in Gescher.

Flat prices mislead — dimensions, wall situation, locking, hinge side decide.

  • from €800
    T30 standard steel doorSingle-leaf, no glass, fitted in Gescher
  • €1,200 – €2,000
    T30 timber doorVeneered or lacquered, single-leaf
  • €1,800 – €3,500
    T90 steel doorBoiler/transformer, possibly self-locking
  • €2,500 – €4,500
    T30/T90 double-leafFoyers, stairwells, wide passageways
  • from €3,500
    F30/F90 glass doorStainless frame, Pyropanel/Promaglas

All prices indicative for Gescher — fixed offer after measurement.

Fire doors in Gescher — FAQ.

  • Maintenance is recommended with every install — DIN-compliant, audit-ready, predictable cost.

Order fire doors for Gescher.

Order fire doors in Gescher — we inspect, we calculate, we install.

Call+49 2861 8114387