Fire-stop penetration seals in Erkelenz

Sealing what needs to be sealed in Erkelenz and Kreis Kreis Heinsberg. Cable seals, pipe stops, combined penetrations. Soft, hard or mortar seals.

Walkthrough in ErkelenzDefect list includedFixed offer
Erkelenz

What a penetration seal achieves.

Penetration seals are building-authority-tested closures of wall and ceiling openings. They prevent fire and smoke spread for the same duration the wall itself is rated for — 30, 60 or 90 minutes. Without a seal, every cable, pipe or duct that crosses the wall becomes a direct path for flames and smoke.

Penetration systems for Erkelenz.

We combine Promat, Hilti and Würth — system-open, brand-neutral in Erkelenz.

  1. 01

    Stock documentation

    Take over multi-brand stock in Erkelenz, consolidate in the penetration plan, prepare for consultant sign-off. Specified per approval in Erkelenz.

  2. 02

    Pipe penetration

    Intumescent collar for plastic pipes, mineral wool insulation for steel — system-dependent, per approval, documented in the penetration plan.

  3. 03

    Cable seal in wall

    Classic in Erkelenz stock: cables through F30/F90 wall, mineral wool with coating or board with collars. Documented in the property log in Erkelenz.

  4. 04

    Combined seal

    Cable and pipe in the same opening — Promat combination, Hilti CFS-CT, Würth fire-stop solution.

  5. 05

    Cable seal in ceiling

    Vertical penetration — usually box-style, accessible from above, expandable for future cables. Specified per approval in Erkelenz.

  6. 06

    Duct fire-stop

    Fire damper or duct seal — coordinated with the concept, integrated into the duct line.

Where we install seals in Erkelenz.

Duct lines
Fire dampers, duct seals — schools, care, offices in Erkelenz.
Plant rooms
Boiler, distribution, transformer — high penetration density, consultant focus. Standard scope in Erkelenz.
Stock survey
Take over multi-brand stock in Erkelenz, inspect, transfer into penetration plan, prepare for authorities. Standard scope in Erkelenz.
Riser shafts
Floor-by-floor sealing — renovation, stock, retrofit in Erkelenz.
Cable trays
Tray penetrations with box seals or aggregate seals.
Stairwell walls
Compartment boundaries with cable and pipe penetrations — mandatory at every building permit in Erkelenz.

Standards.

  • MLAR
    Cable line directive

    Governs electrical line routing in fire protection — applies in NRW.

  • DIN 4102-9
    Cable penetration seals

    Defines the S-rating for cable seals in Erkelenz buildings.

  • EN 1366-3
    European classification

    EI rating for penetration seals — used parallel to DIN, EU-recognised.

  • abZ
    Building-authority approval

    Every system carries an approval number — we deliver the documentation in Erkelenz.

What penetration seals cost in Erkelenz.

Ranges depend on opening size, density and system. Fixed quote after walkthrough.

  • from €80
    Small cable penetrationSingle cable, S30 with coating
  • €150 – €400
    Standard wall cable sealMineral wool + coating, medium density
  • €300 – €800
    Combined sealCable and pipe in one opening
  • from €600
    Duct fire-stopFire damper installed
  • Fixed price
    Stock survey & penetration planLump-sum after walkthrough in Erkelenz

Fixed offer after walkthrough in Erkelenz.

Fire stops in Erkelenz — FAQ.

  • Yes — as long as each position has an approval and the documentation is consistent. We take over stock brand-neutrally.

Have your seals checked for Erkelenz.

Walkthrough in Erkelenz → defect list → fixed offer.

Call+49 2861 8114387