Fire-protective claddings in Eitorf

Fire claddings for steel beams, timber elements and ventilation ducts in Eitorf. F30, F90 and higher — approved Promatect, Knauf fire systems.

Request survey+49 2861 8114387
Existing & newBrand-openOn site weekdays
Eitorf

What fire cladding does.

Unlike fire doors or seals, claddings don't form compartments — they buffer temperature. The steel beam, the duct, the timber stays functional under fire for the defined duration. In Eitorf, this matters most in industrial roofs where a beam collapse means a section collapse.

Cladding types for Eitorf.

What we install in Eitorf depends on the structure, appearance and construction phase.

  1. 01

    Duct cladding

    Promatect-L or equivalent — fully enclosing the duct, per approval, in Eitorf industrial settings. Specified per approval in Eitorf.

  2. 02

    Fire-protective coating

    Intumescent coating — for visible steelwork, where boards would interfere visually.

  3. 03

    Sprayed plaster

    Sprayable, for large-area load-bearing structures in industrial halls where appearance is secondary.

  4. 04

    Shaft cladding

    Lift shafts or service shafts — F90 outside, F30 inside, per concept in Eitorf.

  5. 05

    Timber beam protection

    F30/F60 cladding for existing ceilings — for top-ups, renovation, stock protection in Eitorf. Specified per approval in Eitorf.

  6. 06

    Steel beam F30/F90

    Board cladding with Promatect or Knauf — three-sided or four-sided box around the beam.

Where we cladding in Eitorf.

Duct lines
Ventilation ducts in school, care, office buildings in Eitorf — F90 cladding all-round. Standard scope in Eitorf.
Stairwell structure
Steel staircases with F30 cladding — in stock, new build, as renovation measure.
Hall load-bearing
Steel beams in logistics and production halls in Eitorf — F30 to F90 per concept, audit-ready.
Timber ceiling
Stock cladding for timber-beam ceilings — F30/F60 underside in Eitorf stock. Standard scope in Eitorf.
Lift shaft
F90 shaft wall with cladding — for stock renovation, top-up storeys, new build in Eitorf.
Service shaft
Heating, sewage, ventilation shaft — F90 cladding with inspection openings.

Standards.

  • MLAR
    Cable line directive

    Governs cladding of cable routes — alongside penetration plans, in stock documentation, in new build.

  • DIN 4102-4
    Components under fire

    F30/F90/F120 classification — the foundation, building-authority recognised, in stock and new build.

  • abZ
    Building-authority approval

    Every cladding with approval and conformity declaration.

  • EN 13501-2
    EU classification

    EI ratings for claddings — parallel to DIN, EU-recognised.

What fire claddings cost in Eitorf.

Heavily dependent on component and area — fixed price after survey.

  • from €60/m
    Steel beam F30 board claddingPer linear metre, three-sided
  • €120 – €250/m²
    Duct cladding F90All-round, in line
  • from €80/m²
    Shaft wall F90Lift shaft / service
  • Fixed price
    Timber-beam upgradeLump-sum after walkthrough in Eitorf
  • On request
    Fire-protective coatingPer m² visible area, intumescent

Fixed offer after survey in Eitorf.

Claddings in Eitorf — FAQ.

  • For special-use buildings, in maintenance plans, at renovation completion — yes. Documentation in Eitorf provided.

Plan claddings for Eitorf.

Survey in Eitorf → board order → install. Documentation audit-ready.

Call+49 2861 8114387