Load-bearing structures keep their fire-resistance rating through approved board claddings, fire-protective coatings or mineral-wool build-ups — installed in Bad Laasphe and Region Reg.-Bez. Arnsberg.

Request survey+49 2861 8114387
Existing & newBrand-openOn site weekdays
Bad Laasphe

What fire cladding does.

System selection in Bad Laasphe depends on the bauteil and the visibility. Conservation-grade structures often get intumescent coatings — they meet F-rating without altering geometry. Hidden beams use board cladding for cost and speed.

Cladding types for Bad Laasphe.

What we install in Bad Laasphe depends on the structure, appearance and construction phase.

  1. 01

    Sprayed plaster

    Sprayable, for large-area load-bearing structures in industrial halls where appearance is secondary.

  2. 02

    Duct cladding

    Promatect-L or equivalent — fully enclosing the duct, per approval, in Bad Laasphe industrial settings. Specified per approval in Bad Laasphe.

  3. 03

    Timber beam protection

    F30/F60 cladding for existing ceilings — for top-ups, renovation, stock protection in Bad Laasphe.

  4. 04

    Fire-protective coating

    Intumescent coating — for visible steelwork, where boards would interfere visually. Documented in the property log in Bad Laasphe.

  5. 05

    Steel beam F30/F90

    Board cladding with Promatect or Knauf — three-sided or four-sided box around the beam.

  6. 06

    Shaft cladding

    Lift shafts or service shafts — F90 outside, F30 inside, per concept in Bad Laasphe. Specified per approval in Bad Laasphe.

Where we cladding in Bad Laasphe.

Duct lines
Ventilation ducts in school, care, office buildings in Bad Laasphe — F90 cladding all-round. Standard scope in Bad Laasphe.
Lift shaft
F90 shaft wall with cladding — for stock renovation, top-up storeys, new build in Bad Laasphe. Standard scope in Bad Laasphe.
Service shaft
Heating, sewage, ventilation shaft — F90 cladding with inspection openings. Standard scope in Bad Laasphe.
Hall load-bearing
Steel beams in logistics and production halls in Bad Laasphe — F30 to F90 per concept, audit-ready. Standard scope in Bad Laasphe.
Timber ceiling
Stock cladding for timber-beam ceilings — F30/F60 underside in Bad Laasphe stock.
Stairwell structure
Steel staircases with F30 cladding — in stock, new build, as renovation measure. Standard scope in Bad Laasphe.

Standards.

  • MLAR
    Cable line directive

    Governs cladding of cable routes — alongside penetration plans, in stock documentation, in new build.

  • abZ
    Building-authority approval

    Every cladding with approval and conformity declaration.

  • EN 13501-2
    EU classification

    EI ratings for claddings — parallel to DIN, EU-recognised.

  • DIN 4102-4
    Components under fire

    F30/F90/F120 classification — the foundation, building-authority recognised, in stock and new build.

What fire claddings cost in Bad Laasphe.

Heavily dependent on component and area — fixed price after survey.

  • from €60/m
    Steel beam F30 board claddingPer linear metre, three-sided
  • €120 – €250/m²
    Duct cladding F90All-round, in line
  • from €80/m²
    Shaft wall F90Lift shaft / service
  • Fixed price
    Timber-beam upgradeLump-sum after walkthrough in Bad Laasphe
  • On request
    Fire-protective coatingPer m² visible area, intumescent

Fixed offer after survey in Bad Laasphe.

Claddings in Bad Laasphe — FAQ.

  • Yes — F30/F90 retrofit-able, cladding around existing components, in occupied rooms in Bad Laasphe.

Plan claddings for Bad Laasphe.

Survey in Bad Laasphe → board order → install. Documentation audit-ready.