T60 fire doors

60 minutes fire resistance — the requirement for boiler rooms, transformer stations, archives, lift lobbies and industrial areas with elevated fire loads. EI₂60 classification in accordance with the applicable proofs of usability / T60 in accordance with the applicable proofs of usability. Certified as a full system: leaf, frame, hardware, seals.

Request a quote
60 min fire resistanceSteel / insulatedSmoke-tight "-RS" option
T60 fire doors

60 minutes fire resistance — for areas with elevated fire loads.

A T60 fire door withstands fire and heat for at least 60 minutes in the standard fire test in accordance with the applicable proofs of usability, classified in accordance with the applicable proofs of usability as EI₂60 or nationally as T60 in accordance with the applicable proofs of usability. T60 is typical for boiler rooms ≥ 100 kW, oil storage, transformer stations, archives and fire-wall penetrations between compartments. With "-RS" addition, also smoke-tight in accordance with the applicable proofs of usability.

Variants

Which variant fits depends on the installation context, the existing building and the fire-protection concept — we advise per project.

Standard configuration

Cost-efficient solution for the most common installation contexts — tested systems from established manufacturers.

On request

Bespoke configuration

For non-standard sizes, installation contexts or higher requirements driven by the fire-protection concept or expert reports.

Existing buildings & retrofit

Recertification of existing components or phased replacement — coordinated around live operations.

All prices excl. VAT. Maintenance contracts are quoted on a per-unit basis.

Where T60 is required.

We cover every typical building type — from residential to industrial complexes with hundreds of components per site.

01

Boiler rooms ≥ 100 kW

FeuV NRW mandates T60 for boiler and fuel storage rooms from 100 kW rated load.

02

Transformer & tech rooms

Switchgear, transformers, UPS rooms — T60 separates technical areas from flight paths.

03

Archives & records

Document-safe with T60; often combined with RC3/RC4 burglary resistance.

04

Industrial & storage

Separation of production from storage with high fire loads, hazardous goods, lithium battery storage.

  • applicable proof of usability

    Fire-resistance class T60

    National classification for fire-resistant door assemblies with 60-minute rating.

  • applicable proof of usability

    European classification EI₂60

    Integrity (E) and insulation (I) in the European system.

  • applicable proof of usability

    Smoke-tight assemblies

    Additional "-RS" requirement for escape and rescue routes.

  • FeuV NRW

    Firing ordinance NRW

    Mandates T60 for boiler and fuel-storage rooms from 100 kW.

Advice, installation, service — one hand.

NRW-wide, exclusively with our own installers — no subcontractors.

NRW-wide

Aachen to Bielefeld, Lower Rhine to Sauerland — survey usually within five working days.

Our own installers

No subcontractors. Warranty work and maintenance always trace back to the same people.

Maintenance contracts

We schedule appointments proactively. Inspection record for the fire authority comes with every visit.

  1. 01

    Specification & tender

    Building-code check: T60 or T90? Smoke-tight? Panic hardware? Clarified before tendering.

  2. 02

    Compliant installation

    Per manufacturer certificate (abZ/aBG). Anchors, backfill, interface — fully documented.

  3. 03

    Annual service applicable proof of usability

    Functional checks of hold-open controllers, seals, closers, handles, locks — with inspection protocol.

T60 in detail.

Quote for T60 fire doors.

We measure on site, review the building-code requirement and deliver the right system — installed and documented.

Call+49 2861 8114387